GENERAL INFORMATION, Precautions when working with electrical equipment.
Dismantling
1. Disconnect "negative" battery terminal.
2. Disconnect the block from the coolant temperature sensor.
3. Install a container under the sensor to collect the escaping coolant.
4. Using a tall socket, carefully unscrew the coolant temperature sensor (ECT) and discard the gasket.
Assembly
1. Wipe the mating surfaces of the sensor (ECT) and cooling pump.
2. Put on the coolant temperature sensor (ECT) new sealing washer, screw it in and tighten to 15 Nm.
3. Connect the block to the coolant temperature sensor (ECT).
4. Remove the container from under the engine.
5. Dispose of the coolant and wipe the container.
6. Attach "negative" battery terminal.
7. Check the level of working fluid in the cooling system and top up if necessary.
MAINTENANCE, SERVICE OPERATIONS, Cooling system.
8. If a new sensor has been installed, reconfigure the control system using the TestBook/T4.
Comments on this article