Td6 emission reduction systems
Threaded connection | In the SI system | In lb ft |
Bolts with an internal hexagon of fastening of the valve of system of ventilation of a crankcase | 8 Nm | 6 lb ft |
Injector harness mounting bolts | 2 Nm | 1.5 lb ft |
Bolts of fastening of the valve of recirculation of the fulfilled gases (EGR) | 10 Nm | 7 lb ft |
EGR Solenoid Nuts | 10 Nm | 7 lb ft |
EGR Cooler Allen Bolts | 25 Nm | 18 lb ft |
Hose from charge air cooler to EGR valve | 6 Nm | 4.4 lb ft |
Wait 10 minutes and re-tighten the hose clamp screw from the cooler to the EGR valve | 6 Nm | 4.4 lb ft |
V8 emission control systems
Threaded connection | In the SI system | In lb ft |
Bolts of fastening of the pump of giving of additional air: | ||
Upper | 22 Nm | 16 lb ft |
Lower | 5 Nm | 4 lb ft |
Bolts of fastening of the valve of system of giving of additional air to a collector | 10 Nm | 7 lb ft |
Heated oxygen sensor + | 50 Nm | 37 lb ft |
+ When assembling, apply non-stick paste to the threads of the sensor