Operation of the emergency stop unit
WARNING: Before working on passive safety systems, carefully read the relevant technical documentation.
1. Follow all safety rules when working with passive safety systems.
GENERAL INFORMATION, Safety Precautions When Working on the Airbag System (SRS).
2. Remove the battery emergency disconnect from the vehicle.
RESTRAINT SYSTEMS FOR DRIVER AND PASSENGERS, REPAIR WORK, Battery - emergency shutdown unit (SRS system).
3. Check the condition of the LRT-86-003 fixture and cables supplied with it.
4. Clamp the bracket LRT-86-007/02 in a vise. The vise should clamp the bracket above the bottom flange to prevent the bracket from moving upwards due to detonation. Tighten the vise.
5. Install and secure the emergency stop unit on the LRT-86-007/02 bracket.
6. Connect the cable LRT-86-003/03 of the accessory to the emergency stop unit.
7. Attach the LRT-86-003 tool to the other end of the LRT-86-003/03 cable.
8. Attach tool LRT-86-003 to battery.
WARNING: Ensure that all persons are at least 15 m away from the air bag module.
9. To activate the emergency shutdown unit, press the power button on the fixture body.
10. Disconnect the tool from the battery.
WARNING: When deployed, parts of the airbag become hot and may cause burns. Wait 30 minutes after deployment before touching the airbag module.
11. Disconnect the tool cable from the emergency stop box.
12. Remove the emergency stop unit from the bracket and place in a sealed bag for later disposal.
13. Wipe the bracket with a damp cloth and remove from the vise.
14. Dispose of the used battery kill switch to a designated incineration area.
WARNING: It is forbidden to reuse any parts of the passive safety systems.
NOTE: Do not transport parts of deployed restraint systems in the vehicle interior.