When you enter the key, turn on the ignition (ON state) and receiving permission to start, the LED in the lower left part of the instrument panel will light up for 3 seconds, after which it will turn off. If permission to start is not obtained, the LED will flash 1 time every 2 seconds. The table below lists the fault codes that are logged under certain conditions. For more information.
For more information refer to: Starting system (303-06A Starting system - 3.2L NA - I6, Diagnostics and checks) Electronic controls (303-14A Electronic controls - 3.2L NA - I6, Diagnostics and checks) Electronic controls (303-14B Electronic Controls - 2.2L Duratorq - Td4, Diagnostics and Tests).
Operating mode/Fault | Registration conditions | Ignition status | DTC | Indication |
Examination | Missing | Switching from OFF to ON | Missing | LED on for 3 seconds |
SCU Internal Fault | key introduction | Any | B102496 | Warning message display |
Lost Communication with SCU (SCU not responding) | key introduction | Any | B102487 | Warning message display |
Wrong SCU response | key introduction | Any | B102481 | Warning message display |
SCU not programmed | key introduction | Any | B102451 | Warning message display |
The dongle is not responding | key introduction | Any | B102408 | Warning message display |
Invalid transceiver response | key introduction | Any | B102581 | Warning message display |
Communication error with TP | key introduction | Any | B102408 | Warning message display |
The number of programmed keys is less than the minimum | Manufacturer/Dealer | Any | B10D800 | No indication |
Key not programmed | Manufacturer/Dealer | Any | B10D751 | No indication |
SCL not programmed | Manufacturer/Dealer | Switching from OFF to ON | B102651 | Warning message display |
Lost communication with ECM | Missing | Any | U010000 | Warning message display |