Examination
1. The closed door must fit snugly against adjacent panels. The gap between the door and the corresponding body elements must be the same.
Adjustment
1. Loosen the 2 Torx bolts securing the door lock retainer.
2. Adjust the position of the latch in such a way as to ensure normal fit of the door to adjacent panels and normal opening and closing of the door.
3. Tighten the Torx bolts to 10 Nm.